EMFSafeSwitch

How to install an EMF Safe Switch

The pre-wired pigtail has wires that will connect with items in your main electrical panel. They are labeled and are as follows:   CB wires are to be attached to the Circuit Breakers; BC wires are to be attached to the home's Branch Circuits. This installation is very straightforward but should be performed by a licensed  home electrician.  Once the panel is mounted and the pigtail connected, the process should take less than one hour.  Refer to our Installation Instructions (PDF) below for more detail and specific instructions on zoning.

Product Specifications

EMFSafeSwitch

The EMFSafeSwitch is built in America in a 508A UL industrial control panel shop and come as a complete unit ready to install, which should only take an hour maybe two. Being UL listed they are safe for your home, will pass building inspection and not void your home owners insurance (which a non-UL listed "kit" could).


DESIGN FEATURES

  • The EMFSafeSwitch comes fully wired with a pre-wired pigtail to minimize installation time and ensure proper hook-up.
  • The EMFSafeSwitch comes ready for control by use of low voltage wiring to a remote switch installed in your bedroom or optional RF (radio frequency unit) that may be installed at any time.
  • The EMFSafeSwitch is built to industrial UL 508 standards utilizing UL listed components ensuring a safe, reliable product.
  • Each unit is fully tested for functionality.


DIMENSIONS:

  • Enclosure measures 12"x 12"x 4" or 12"x 18"x 4"
  • Pigtail measures approximately 19" with an approximate additional 36" of wiring extending beyond conduit end
  • Antenna (extended range) projects less than one inch from the box


ELECTRICAL:

  • 120VAC , 20 Amp maximum for each branch circuit
  • 120VAC , 20 Amp maximum for powering The EMFSafeSwitch
  • 240VAC, not standard -- if you have such a control need, inquire


LOW VOLTAGE SWITCHING:

  • 24VAC Type II transformer


RF UNIT:

  • 24 VAC
  • Antenna, standard: 2 dB gain/dipole --RMA connectivity
  • Antenna, extended range:


ENVIRONMENT:

  • Type 1 enclosure (indoor, standard unit)
  • Other enclosures , not standard (Type 3 outdoor, flush, etc..)-- if needed, inquire

image185

This is cool . . .

This is a note to Dan and the EMFSafeSwitch team: “I installed my EMFSleepSwitch and it is so cool! I’m not an electrician but am a DIY guy and it was a piece of cake. It was so cool to hit the fob buttons and turn my zones on and off. . . Getting a fob for each zone was a bonus . . . didn’t anticipate that. Anyway, my wife is really enjoying using the lights in the bedroom to read at night, then killing everything when it’s time to sleep. Thanks to you all for a great product!” .  .  .  Steve

installation instructions

Step #1:

Step #3:

Step #2:

image186

  Mount the EMFSafeSwitch on the wall and secure the pigtail to the main electrical panel. 

Step #2:

Step #3:

Step #2:

image187

 Label your selected circuit breakers.  Identify each circuit breaker's connected branch circuit home line.

Disconnect the branch circuit home lines from their circuit breakers (not shown).

Step #3:

Step #3:

Step #3:

image188

Attach the CB-1 wire from EMFSafeSwitch to your #1 circuit breaker.

Step #4:

Repeat Steps 3 and 4

Step #3:

image189

Connect the BC-1 wire from the EMFSS to your  #1 branch circuit home line.

Repeat Steps 3 and 4

Repeat Steps 3 and 4

Repeat Steps 3 and 4

image190

for all of your identified circuit breakers and their associated branch circuit home lines.

Step #5:

Repeat Steps 3 and 4

Repeat Steps 3 and 4

image191

Attach the power wire from the EMFSS to a 15 or 20 amp breaker.

Step #6:

Step #6:

Step #6:

image192

Attach the neutral (white) and the ground (green) wires from the EMFSS to their standard main panel connection points.

Step #7:

Step #6:

Step #6:

image193

Select control and zone options with designated switches in the EMFSS.

Step 7b

Step #6:

Step #8:

image194

Attach low voltage wire (customer supplied) to connection nuts if hardwired control option is desired.

Step #8:

Share the big newsStep #9:

Step #8:

image195

Finished install.

Share the big newsStep #9:

Share the big newsStep #9:

Share the big newsStep #9:

image196

Velcro the remote nearby your bed for accessibility and ease of use.

Downloads

bvk-setup-levels (pdf)Download
BVK Report (pdf)Download
BEDROOM-EMF-MITIGATION-USING-THE-BODY-VOLTAGE-TESTING-METHOD-36ee (pdf)Download
International_EMF_Scientist-Appeal (pdf)Download
Pall-Letter-to-CalLegis-FINAL-8-7-17 (pdf)Download
Solid-Remote-instructions (pdf)Download
install-instruct (pdf)Download

Store

Emfsafeinc - Emfsleepsafe - emfkillswitch - emfsleepswitch - EMFsafeSwitch


feel free to call us but please go through the web site first


Oregon main - 541-944-EMF0 (3630)

Operations - 972-849-9500

Technical Support - 541-538-9529


support@emfsafeinc.com


Copyright © 2021 EMFSafe - All Rights Reserved.